description *** ET *** 
port link-type access 
port default vlan 11 
stp edged-port enable 
poe power-off time-range POE 
port-security enable 
port-security protect-action protect 
port-security aging-time 5 
storm-control broadcast min-rate 1488095 max-rate 1488095 
undo poe enable 
undo shutdown 
#

description *** BT-PORT *** 
port link-type access 
port default vlan 40 
loopback-detect enable 
stp root-protection 
poe power-off time-range POE 
storm-control broadcast min-rate 1488095 max-rate 1488095  
undo shutdown 
#

description *** IDARI *** 
port link-type access 
port default vlan 20 
loopback-detect enable 
stp root-protection 
stp edged-port enable 
port-security enable 
port-security protect-action protect 
port-security max-mac-num 1 
port-security aging-time 10 
storm-control broadcast min-rate percent 100 max-rate percent 100 
undo poe enable 
undo shutdown 
#

description *** AP *** 
port link-type trunk 
port trunk pvid vlan 10 
port trunk allow-pass vlan 10 to 11 30 50 60 
loopback-detect enable 
stp root-protection 
stp edged-port enable 
storm-control broadcast min-rate percent 100 max-rate percent 100 
poe power-off time-range POE 
undo shutdown
#